Readability:1mg,Max Capacity220g-2200g;Brand New Monolithic Sensor
New Super new cell sensors - accurate, fast, stable and trustworthy - fully compliant with 21CFR Part11 - fully traceable
Full touch screen operating system, fully automatic calibration and adjustment technology,
Automatic level adjustment function,
Built-in 12 applications, printout, data output in line with GLP/GMP requirements
Max capacity
320g220g
Balance series
XE系列
Minimum initial weighing
100mg500g
Interface
RS232
Calibration
External
Documents
PrintBasic electronic documents
User administration
User authorityPassword protect
Application industries
LaboratoryScientific researchEducation
Adopt new super monolithic sensor technology - accurate, fast, stable and reliable.
|
Model |
XE223 |
XE323 |
XE523 |
XE623 |
XE1023 |
XE2023 |
|
Max capacity(Max) |
220g |
320g |
520g |
620g |
1200g |
2200g |
|
Readability(d) |
1mg |
1mg |
1mg |
1mg |
1mg |
1mg |
|
Repeatability(5% load) |
||||||
|
Tolerance |
1mg |
1mg |
1mg |
1.5mg |
1.5mg |
2mg |
|
Typical value |
1.5mg |
1.5mg |
1.5mg |
2mg |
2mg |
3mg |
|
Repeatability(approx. 100% load) |
||||||
|
Tolerance |
2mg |
2mg |
2mg |
2mg |
2.5mg |
3mg |
|
Typical value |
2.5mg |
2.5mg |
2.5mg |
2.5mg |
3mg |
5mg |
|
Linearity deviation |
||||||
|
Tolerance |
2mg |
2mg |
2mg |
2mg |
2.5mg |
3mg |
|
Typical value |
2.5mg |
2.5mg |
2.5mg |
2.5mg |
3mg |
5mg |
|
Off-center load deviation ( positions according to OIML R76) |
||||||
|
Test weight |
100g |
200g |
200g |
200g |
500g |
1000g |
|
Tolerance |
2mg |
2mg |
2mg |
2mg |
2.5mg |
3mg |
|
Typical value |
2.5mg |
2.5mg |
2.5mg |
2.5mg |
3mg |
5mg |
|
Sensitivity drift (+10℃~+30℃) |
5ppm/K |
5ppm/K |
5ppm/K |
5ppm/K |
6ppm/K |
8ppm/K |
|
Tare max capacity:<100% max capacity |
||||||
|
Accuracy class ( according to Directive 2014 | 31 | EU) |
Ⅱ |
Ⅰ |
||||
|
Verification scale interval(e) ( according to Directive 2014 | 31 | EU) |
1mg |
10mg |
10mg |
10mg |
10mg |
10mg |
|
Minimum load ( according to Directive 2014 | 31 | EU) |
100mg |
100mg |
100mg |
100mg |
100mg |
100mg |
|
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 |
||||||
|
Optimum minimum initial weighing |
82mg |
82mg |
82mg |
82mg |
82mg |
82mg |
|
Typical minimum initial weighing |
1.3mg |
1.3mg |
1.3mg |
1.3mg |
1.3mg |
1.3mg |
|
Typical stabilization time |
2s |
2s |
2s |
2s |
3s |
3s |
|
Typical measurement time |
3s |
3s |
3s |
3s |
5s |
5s |
|
Recommended calibration weight |
||||||
|
External calibrated test weight |
200g |
200g |
200g/500g |
200g/600g |
500g/1000g |
1000g/2000g |
|
Accuracy class (according to OIML R111-1) |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
|
Dimensions |
||||||
|
L x W x H |
240mm×430mm×380mm |
|||||
|
Weighing pan |
140mm×140mm |
|||||
|
Weighing chamber height |
248mm |
|||||
|
Net weight |
approx. 9.5kg |
|||||
|
Ambient conditions |
||||||
|
Operation temperature |
18℃~23℃ |
|||||
|
Relative humidity |
50%RH~75%RH |
|||||
|
Warm-up temperature fluctuation |
≤1°C/h |
|||||
|
Power supply |
100V-240VAC 50HZ/60HZ 1.0A-0.5A |
|||||
1.Pharmaceutical software package
2.Portable micro printer