Readability: 0.01mg,Capacity: 31g-220g;Brand New Monolithic Sensor
New super monolithic sensor technology - accurate, fast, stable and reliable
Compliance with 21CFR Part 11 - full traceability
Operating system with full touch screen
Automatic calibration and adjustment technology
Automatic leveling function
Built-in multi-applications, print output, & data output meet GLP/GMP requirements
Readability (d)
0.01mg
Max capacity
31g51g81g120g220g
Minimum initial weighing
1mg
21 CFR Part 11
Applicable
Ionizer
Optional
Interface
USB-CRS232RS485
Type of balance
Semi-micro Balance
Application industries
High-end LaboratoryPharmaceutical Industry
|
Model |
XE305S |
XE505S |
XE805S |
XE1205S |
XE2205S |
|
Max capacity(Max) |
31g |
51g |
81g |
120 |
220 |
|
Readability(d) |
0.01mg |
0.01mg |
0.01mg |
0.01mg |
0.01mg |
|
Repeatability(5% load) |
|||||
|
Tolerance |
0.01mg |
0.01mg |
0.01mg |
0.015mg |
0.02mg |
|
Typical value |
0.02mg |
0.02mg |
0.02mg |
0.025mg |
0.03mg |
|
Repeatability(approx. 100% load) |
|||||
|
Tolerance |
0.015mg |
0.015mg |
0.015mg |
0.02mg |
0.025mg |
|
Typical value |
0.02mg |
0.02mg |
0.03mg |
0.03mg |
0.05mg |
|
Linearity deviation |
|||||
|
Tolerance |
0.015mg |
0.015mg |
0.015mg |
0.02mg |
0.03mg |
|
Typical value |
0.02mg |
0.02mg |
0.02mg |
0.03mg |
0.03mg |
|
Off-center load deviation ( positions according to OIML R76) |
|||||
|
Test weight |
20g |
50g |
50g |
100g |
200g |
|
Tolerance |
0.02mg |
0.02mg |
0.03mg |
0.04mg |
0.04mg |
|
Typical value |
0.05mg |
0.05mg |
0.05mg |
0.06mg |
0.08mg |
|
Sensitivity drift (+10℃~+30℃) |
8 ppm/K |
||||
|
Tare max capacity:<100% max capacity |
|||||
|
Accuracy class |
Ⅰ( according to Directive 2014 | 31 | EU) |
||||
|
Verification scale interval(e) ( according to Directive 2014 | 31 | EU) |
0.1mg |
0.1mg |
0.1mg |
0.1mg |
0.1mg |
|
Minimum load ( according to Directive 2014 | 31 | EU) |
1mg |
1mg |
1mg |
1mg |
1mg |
|
Minimum initial weighing :according to USP(United States Pharmacopeia) Chap. 41 |
|||||
|
Optimum minimum initial weighing |
0.82mg |
0.82mg |
0.82mg |
0.82mg |
0.82mg |
|
Typical minimum initial weighing |
1.3mg |
1.3mg |
1.3mg |
1.3mg |
1.3mg |
|
Typical stabilization time |
3s |
3s |
3s |
3s |
5s |
|
Typical measurement time |
5s |
5s |
5s |
5s |
8s |
|
Recommended calibration weight |
|||||
|
External calibrated test weight |
20g |
50g |
50g |
100g |
200g |
|
Accuracy class (according to OIML R111-1) |
E1 |
E1 |
E1 |
E1 |
E1 |
|
Dimensions |
|||||
|
L x W x H |
240mm×430mm×380mm |
||||
|
Weighing pan |
85mm×85mm |
||||
|
Weighing chamber height |
248mm |
||||
|
Net weight |
approx. 9.86kg |
||||
|
Ambient conditions |
|||||
|
Operation temperature |
18℃~23℃ |
||||
|
Relative humidity |
50%RH~75%RH |
||||
|
Warm-up temperature fluctuation |
≤1°C/h |
||||
|
Power supply |
100V-240VAC 50HZ/60HZ 1.0A-0.5A |
||||
♦ GB/T26497-2022 Electronic Balances
♦ JB/T9511-1999 Balance-packing Requirements
♦ OIML R76-2(2007E) International Recommendation: Non-automatic weighing instruments
1.Automatic door technology
2.Automatic electrostatic removal technology
3.Second screen
4.Pharmaceutical software package
5.External draft shield
6.Gesture sensor
7.Portable micro printer